10. Use the arrow keys to select the Save Current Settings option.
Press
Enter
to save all current settings; then press
Set-Up
to exit the
Set-Up Directory.
Your operating system may have other requirements for using serial
communications devices. Refer to your system software manual.
3.2.1.2 Asynchronous Controllers with Modem Support
Using serial devices with modem support requires that you install two
modems: one connected to the system and one connected to the remote
terminal. Both must be connected to phone lines.
Before using modems with your system, check the following:
1. Make sure each modem is connected to the system.
2. Make sure the modem is properly installed and connected to a phone
jack.
3. Set controls on the modem according toinstructions in the modem users
guide.
Before using the modem connected to the remote terminal, check the
following:
1. Make sure the modem is properly installed and connected to a phone
jack.
2. Set controls on the modem according toinstructions in the modem users
guide.
3. Check the settings on the terminal attached to the modem. Depending
on the type of modem and the type of lines used, the baud rate may
be 300, 1200, or 2400. Other settings should be the same as those
described in the previous section.
Before using a phone line with modem support, you must set certain
parameters such as line speed. See your system software manuals for
details.
3.2.2 Synchronous Controllers
The following synchronous controllers are available for your VAX 4000
system:
DIV32—DEC Integrated Services Digital Network (ISDN) controller
DPV11—Single-line programmable controller
DSV11—Dual-line controller
3–40 VAX 4000 Model 200 (BA430) Operation